PAT testing vs EICR is one of the most common points of confusion for business owners, and many assume that one covers the other. It does not. They test different parts of your electrical system, they are driven by different risks and they are done at different intervals.
What is an EICR?
An Electrical Installation Condition Report is an inspection and test of the fixed electrical installation: the wiring, distribution boards, circuit protection, sockets, switches, lighting circuits and earthing. It tells you whether the installation is safe to keep using and lists any defects with a classification code.
In the PAT testing vs EICR question, the EICR is the one that covers the wiring behind the walls. Our facilities manager's guide to the EICR explains the process, and our EICR electrical testing page covers the service.
What is PAT testing?
Portable appliance testing covers equipment that plugs in and can be moved: kettles, desk lamps, monitors, extension leads, power tools, heaters, vacuum cleaners and similar items. It combines a visual inspection with electrical tests, depending on the type of equipment, to confirm each item is safe to use.
PAT testing vs EICR: the key differences
What it covers. PAT testing covers portable and plug-in equipment. An EICR covers fixed wiring and distribution.
Typical test. PAT testing is a visual check plus electrical tests on each item. An EICR is an inspection and test of every circuit.
Frequency. PAT testing intervals are based on risk, equipment type and environment. An EICR is commonly needed every five years for commercial premises.
Result. PAT testing gives a pass or fail for each appliance. An EICR is satisfactory or unsatisfactory, with C1, C2, C3 and FI codes.
Is PAT testing a legal requirement?
There is no law that names PAT testing or sets a fixed interval. The Electricity at Work Regulations 1989 require electrical equipment to be maintained so that it does not cause danger, and PAT testing is a common way to show that you are doing so.
HSE guidance is risk based. Equipment used in harsh environments, or by many people, or that is moved around often, needs checking more frequently than a monitor on an office desk. Neither PAT testing nor an EICR is named in law, but both are accepted ways of showing that you maintain your equipment.
How often should each be done?
Portable equipment. Combine regular user checks (looking for damaged cables, plugs and casings) with formal inspection and testing at intervals set by a risk assessment. A workshop with heavy use of power tools will test more often than a low-risk office.
Fixed installation. Five years is the usual interval for commercial premises, shorter for higher-risk environments or where your insurer or lease requires it.
Which does your business need?
Most commercial premises need both. A clean PAT record does not tell you anything about the state of the wiring behind the wall, and a satisfactory EICR does not cover the kettle in the kitchen. Treating them as two parts of one compliance routine is the simplest approach.
Common questions
How often should PAT testing be done? There is no fixed legal interval. Frequency depends on a risk assessment, with harsher environments and heavily used equipment tested more often than a monitor on an office desk.
Does an EICR include PAT testing? No. An EICR covers the fixed installation, such as wiring and distribution boards. Portable appliances are tested separately.
See also our guide to planned electrical maintenance, and the HSE pages on electrical safety at work.
Bowers Contracting carries out commercial EICRs for businesses across Milton Keynes, Northampton, Bedford and the surrounding area, and every report we issue is backed by our NICEIC Approved Contractor status.
Call 01908 040 294 or email mike@bowerscontracting.co.uk to arrange an EICR for your premises.