Many commercial buildings hide electrical risks. The most common and dangerous issues found in commercial properties and how a qualified electrician fixes them.

  • NICEIC Approved Contractor
  • Milton Keynes and surrounding areas
Control panel and fire alarm units installed in a commercial building

Electrical faults are a recognised cause of fires in commercial buildings in the UK, and many of them happen in buildings where the owner or manager had no idea there was a problem.

The trouble with electrical risk is that it is largely invisible. Deteriorating cables, overloaded circuits and inadequate earthing do not announce themselves until something goes wrong, and by then the consequences can be serious for your people, your property and your business.

This guide covers the most common hidden electrical risks in commercial buildings and what a qualified electrician will do about them. See our EICR testing page for how we inspect an installation.

Ageing wiring and insulation degradation

Cables do not last forever. The plastic insulation around the conductors becomes brittle over time, particularly where there are temperature extremes, UV exposure or contact with oils and chemicals. As insulation breaks down, the risk of short circuits, earth faults and fire goes up.

In older commercial properties, particularly those built before the 1980s, it is not uncommon to find rubber-insulated wiring that is well past its safe working life. It often looks intact on the surface but can be badly degraded inside.

A thorough EICR identifies deteriorating cables through insulation resistance testing, and a qualified electrician can then advise on rewiring priorities based on what is found.

Overloaded circuits

The electrical load in most commercial premises has grown since the installation was designed. More computers, more equipment, more heating and cooling and now EV charging all add up to a demand the original installation was never meant to meet.

When a circuit carries more current than it was designed for, the cable heats up. Over time that degrades insulation, loosens connections and increases the risk of fire. Overloaded circuits may show up as regularly tripping breakers, warm sockets or switches, or flickering lights, but sometimes there is no warning at all.

Fixing overloaded circuits usually means redistributing loads, upgrading cable sizes and, in some cases, adding new circuits from an upgraded distribution board.

Poor or missing earthing and bonding

Earthing and bonding make sure fault current flows safely to earth rather than through a person who touches faulty equipment. In commercial and industrial premises, where metalwork, pipework and equipment are often interconnected, correct earthing and bonding is critical.

Poorly earthed installations are especially dangerous because they can appear to work normally until someone receives a serious shock. Earthing faults are not always visible and need proper testing to find.

Unsafe DIY or non-compliant electrical work

In premises that have changed hands, changed use or been modified by unqualified people, it is common to find electrical work that does not meet current standards, or any standards at all.

Sockets added without proper circuit protection, lighting circuits extended beyond their safe capacity and distribution boards altered without documentation are all common findings in commercial EICRs. Non-compliant work can affect your insurance, creates liability risk and in some cases is an immediate safety hazard.

Inadequate RCD protection

Residual current devices (RCDs) switch off the power within milliseconds if they detect a fault current, fast enough to help prevent a fatal shock. Current regulations require RCD protection on most circuits, but older installations often have little or none.

Adding RCD protection is a relatively straightforward upgrade that makes an existing installation much safer. In many cases it can be done as part of a distribution board upgrade without rewiring the whole building.

Incorrect or missing circuit labels

This one sounds minor but has real consequences. In an emergency, such as a fault, a fire or a maintenance job that needs quick isolation, an unlabelled or wrongly labelled board can cost critical minutes. For large premises, proper labelling and as-built drawings are essential.

What to do about hidden electrical risks

The starting point is an Electrical Installation Condition Report from a qualified, NICEIC approved electrician. It gives you an assessment of the installation, lists every observed defect and sets out a priority order for remedial work.

From there, a planned programme of remediation, starting with C1 and C2 findings, brings the installation up to a safe and compliant standard.

Bowers Contracting carries out commercial EICRs and remedial electrical work across Milton Keynes, Northampton and the surrounding area. As a NICEIC Approved Contractor, we test and certify the work we do.